DYNA-GLAS
TM
CENTRIFUGAL PUMPS
WITH INTEGRAL TRAP
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
5MPRA Series MODELS
5MPRA6C-146 5MPRA6C3-146
5MPRA6D-147 5MPRA6D3-147
5MPRA6E-148 5MPRA6E3-148
5MPRA6F-156 5MPRA6F3-156
STA-RITE FOREIGN SALES CORP.
175 WRIGHT STREET, DELAVAN, WISCONSIN 53115 USA
Telephone: (414) 728-5551; Telefax: (414) 728-4461
Cable: STAREX; Telex: (ITT) 4970245
© 1994, Sta-Rite Industries, Inc. Printed in U.S.A. S289 (Rev. 3/17/94)
This manual should be furnished to
the end user of this pump; its use will
reduce service calls and chance of
injury and will lengthen pump life.
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - WITH INTEGRAL TRAP

DYNA-GLASTMCENTRIFUGAL PUMPSWITH INTEGRAL TRAPO W N E R’ S M A N U A LINSTALLATION, OPERATION & PARTS5MPRA Series MODELS5MPRA6C-146 5MPRA6C3-1465M

Page 2 - LIMITED WARRANTY

10Pump Reassembly/Installing New Seal1. Ceramic seat must be clean and free of dirt, grease, dust, etc. Wet outeredge with small amount of liquid dete

Page 3

11Clogged pipe/trap/impeller, worn impeller:7. Make sure suction trap is not clogged; if it is, clean trap and strainer.8. Make sure impeller is not c

Page 4 - INSTALLATION

123456788A8BBox ABox A1112131415B15A1617181920212223910012 0394BOX AFor quick disconnect pipe connection parts:Adapter Union Pkg...

Page 5 - Fittings:

2‘5MPRA’ SERIES PUMP WITH TRAP To avoid unneeded service calls, prevent possible injuries, and get the mostout of your pump, READ THIS MANUAL CAREFULL

Page 6 - ELECTRICAL

3READ AND FOLLOW ALLINSTRUCTIONS!This is the safety alert symbol. When you see this symbol on your systemor in this manual, look for one of the follow

Page 7 - OPERATION

4INSTALLATIONOnly qualified, licensed personnel should install pump and wiring.Pump mount must:Be solid - Level - Rigid - Vibration free. (To reduce v

Page 8 - OVERTIGHT

5Piping:Use at least 1-1/2" (38mm) pipe (use 2"(51mm) pipe if possible). Increase sizeif a long run is needed. When using 1-1/2" pipe,

Page 9 - PUMP SERVICE

6ELECTRICALGround motor before connecting to electrical power supply. Failure toground motor can cause severe or fatal electrical shock hazard.Do not

Page 10 - TROUBLESHOOTING GUIDE

7OPERATIONNOTICE: NEVER run pump dry. Running pump dry may damage seals, caus-ing leakage and flooding. Fill pump with water before starting motor.Bef

Page 11

8Drain all water from pump and piping when expecting freezing temperaturesor when storing pump for a long time (see instructions below).Keep motor dry

Page 12 - 1/2 through 1-1/2 HP Models

9PUMP SERVICEPump should only be serviced by qualified personnel.Be sure to prime pump (Pg. 7) before starting.Before removing trap cover:1. STOP PUMP